Group: 1405
Suitable for quick and safe installing of channel 27 to concrete ceilings or walls and masonry constructions (of calcareous sandstone, solid bricks, clinker bricks, natural stone). To be applied in closed rooms - not suitable for damp locations.
The nail head diameter is adapted exactly to the hole and hole pattern of the channels 27.
An impact screwdriver is best suitable for mounting, using a T30 Torx bit. For subsequently adjusting the component to be connected, unscrew the Bolt Screw Anchor a few millimetres and tighten it again afterwards.
| Perm. load (centric tension) in the tension zone for install. [kN] solutions in concrete ≥ B25 (max. B55) acc. to approval | 0.5 |
| Permissible load in the pressure zone (concrete ≥ B25) [kN] | 2.0 |
| Centre distance a ≥ [mm] | 160 |
| Edge distance ar ≥ [mm] | 80 |
| Minimum thickness of component d ≥ t + 50 mm ≥ [mm] | 105 |
| Nominal diameter of drill [mm] | 6 |
| Cutting diameter ≤ [mm] | 6.4 |
| Minimum depth of bore hole t ≥ [mm] | 55 |
| Minimum setting depth ≥ [mm] | 45 |
| Maximum tigthening torque when mounting [Nm] | 20 |
For brick walls respect a distance between the fixations and the joggle joints of the bricks of min. 30 mm, otherwise halve the load!
| Material: | Steel, case-hardened, tempered steel, electro-galvanised |
DIBt Approval No.: Z-21.1-1503:
Approved by the DIBt in the concrete tension zone for mounting light overhead facings and sub-ceilings as well as statically comparable installations up to 1 kN/m² exposed to mainly dead loading.
Fire resistance category: F120 (Fmax = 0.5 kN)
| Type | L [mm] |
Screw tool |
W [kg] |
Quantity/ [pack] |
Part- No. |
|---|---|---|---|---|---|
| MMS-PR 7.5 x 50 | 50 | T 30 | 0.02 | 100 | 157959 |