Group: 1856
In combination with a channel, End Support WBD is particularly suitable
Normally, two anchors grouped opposite to each other and along the load axis are sufficient. Only in exceptional cases (e.g. high props in frameworks) four anchors are required.
Tighening torque for hexagon bolts ≥ 40 Nm.
For ceiling mounting under high loads (up to 7.0 kN), we recommend the use of at least one fully traversing bolt for connecting the channel to the End Support WBD (for examples see "Installation Guidelines").
| Type | Suitable for Sikla channel | A [mm] | s [mm] | B [mm] | b [mm] | h [mm] | C [mm] |
|---|---|---|---|---|---|---|---|
| 41/21-31 | 41/21/2.0 - 41/31/2.0 | 135 | 6 | 100 | 25 | 11 | 95 |
| 41/41-45 | 41/41/2.5 | 135 | 6 | 100 | 25 | 11 | 95 |
| 41/41-45 D | 41/41/2.5 D | 210 | 8 | 170 | 25 | 13 | 125 |
Working load for Wall mounting:
See tables on load charts for End Support WBD in chapter "Brackets"
The figures apply on walls if two anchors of the load class as stated are used.
Working load for Ceiling mounting:
The permissible maximum vertical load for ceiling mounting with Holding Bracket amounts to 2.0 kN. Using at least one traversing bolt (class 8.8) 7.0 kN.
| Material: | Steel, HCP |
| Type | W [kg] |
Quantity [pack] |
Part- No. |
|---|---|---|---|
| 41/21-31 | 0.73 | 10 | 198063 |
| 41/41-45 | 0.83 | 10 | 198070 |
| 41/41-45 D | 2.46 | 5 | 198100 |